Proposal / 01 of 12

Battery Connection
Assembly Inspection

CAMERA INSPECTION SYSTEM

The proposed system checks assembly sequence and final connection condition. It records results and evidence before the unit proceeds to the next station.

PGQ194 zones32 CAD inventory entries

PGQ19 battery assembly station.

Station concept with assembly table, battery fixture, overhead camera, operator display and barcode scannerEnlarge image
Station concept. Final camera configuration follows coverage testing.

Proposal / 02 of 12

Proposed Scope

Inspection, operator guidance and traceable records for the assembly station.

System elementProposed function
Camera inspectionCheck assembly sequence and final connection condition.
Operator KioskDisplay the current item, progress, results and NG reasons.
Engineering & QualityManage model packages, items, programs, station settings and inspection history.
Programs by battery typeSelect the inspection sequence for the identified battery type.
Inspection recordsStore results, timestamps, images and assembly events.
Station outputsSend OK/NG results, affected items and steps to the next station, with andon indication.
Testing and operating guidanceTest the system on the actual process and provide operating instructions.

The final configuration follows point mapping, the customer SOP and station interface requirements.

Proposal / 03 of 12

Inspection Station Layout

Station concept with assembly table, battery fixture, overhead camera, operator display and barcode scannerEnlarge image
Initial one-camera concept. Final quantity and placement follow coverage testing.
Concept illustration, not a fabrication drawing. The monitor shows an early interface concept.
01

Assembly table and fixture

Hold the battery in position.

02

Cameras and lighting

Capture assembly activity and connection features.

03

Operator Kiosk

Show instructions and inspection results.

04

Barcode scanner

Select the program by battery type.

05

Station computer

Run inspections and store evidence.

Proposal / 04 of 12

Inspection Coverage

PGQ19 battery pack CADEnlarge image
PGQ19 pack CAD / original proposal, slide 4.
ZoneEntriesPlanned checks
Module-row8Sequence, seating and locking
BMS12Sequence and connection condition at mapped points
HVIL / interlock7Sequence and installation criteria for 5 QT and 2 interlock entries
Busbar5Sequence and agreed visual connection criteria
32CAD inventory entries

Drawing review maps entries to physical inspection points. Locking criteria apply where relevant.

Blue highlights come from the source CAD. The interlock detail does not show the entire HVIL inventory. Camera inspection does not measure torque, HVIL continuity or BMS electronic function.

How it works / 05 of 12

Operator Workflow

STEPOPERATORSYSTEM
01Place the battery

Place the battery in the fixture.

Wait for identification.

02Select the program

Scan the identifier according to the agreed procedure.

Select the program and create a session ID.

03Install the item

Follow the item shown on the display.

Trigger inspection when hand activity enters the zone.

04Complete installation

Complete the manual installation.

Check the assembly event and final condition.

05Follow the result

Continue or follow the NG guidance.

Record the result and determine the next step.

06Final result

Follow the final inspection result.

Store evidence before sending the station output.

Each item is presented as one step.

All steps must follow the SOP sequence. No manual capture is required for each connector.

Image activity triggers inspection without a PLC part-present signal. Hand entry or exit alone does not confirm completed installation.

How it works / 06 of 12

Inspection Results

StatusMeaning
IN PROGRESSAssembly or inspection is still in progress.
OKRequired sequence and condition checks pass, and results and evidence are stored.
NGA sequence violation or nonconforming condition has been confirmed.
NOT VERIFIEDEvidence or inspection capability is insufficient to complete the assessment.
SEQUENCE VIOLATION EXAMPLE
Required sequence (example)
MR-01MR-02MR-03
Recorded events (example)
MR-01 completedMR-03 completed
NG: SEQUENCE

MR-02 remains incomplete when MR-03 is installed.

The original NG result remains on record.

Installing MR-02 afterward does not clear the violation. Authorized personnel determine disposition according to the SOP.

An unrecorded installation event leaves the sequence unverified. An item awaiting installation is not automatically NG. NG means nonconforming.

How it works / 07 of 12

Operator Kiosk

OPERATOR SCREEN ILLUSTRATION
Connection InspectionIllustrative data
Battery typePGQ19
Session IDDEMO-SESSION-0001
ProgramPGQ19 / v1.0
IN PROGRESS
Inspection area: CAD illustrationModule-row
PGQ19 pack CAD illustrating the inspection area
MR-01OK
MR-02Current item
MR-03Pending

Actual item positions follow drawing review.

CURRENT ITEM / MODULE-ROW

Install MR-02

MR-02 not installed

Step
02
Inspection criteria
Seated and locked
Previous step
MR-01 / OK

Item IDs and sequence are illustrative.

Module-row1/8
BMS0/12
HVIL0/7
Busbar0/5
Program progress1/32 items OK

Enlarge screen illustration

SEPARATE EXAMPLE / DEMO-SESSION-0002

MR-03 installed
before MR-02

Expected item: MR-02

NG: SEQUENCEContact QualityOriginal result retained.

Two different session examples. The CAD image illustrates the inspection area.

How it works / 08 of 12

Engineering & Quality

ENGINEERING & QUALITY SCREEN ILLUSTRATION
Program ConfigurationIllustrative data
ENGINEERING & QUALITY
BATTERY TYPE / PGQ19

PGQ19 Program

Program version v1.0 / illustrative sequence

32CAD inventory entries

Program excerpt / 3 items

StepItemModel packageModel version
01MR-01Connection Model Av1.0
02MR-02Connection Model Av1.0
03MR-03Connection Model Bv1.0

Programs order physical items. One model package can serve multiple items after validation at each point.

Module-row 8/BMS 12/HVIL 7/Busbar 5
ITEM DETAILS

MR-02

Zone
Module-row
Model package
Connection Model A
Model version
v1.0
SOP criteria
Seated
Locked

Configuration changes are tested before use in subsequent sessions.

Enlarge screen illustration

Engineers configure items and test changes before use.

Quality personnel review records and record unit disposition.

The kiosk and Engineering & Quality are separate applications. Active sessions retain their starting configuration.

How it works / 09 of 12

Models, Items and Programs

01 / CAPABILITY

Model

Ready-to-use inspection
package and version.

Connection Model A / v1.0
02 / PHYSICAL POINT

Item

Area, SOP criteria
and one assigned model.

MR-01 and MR-02
03 / SOP SEQUENCE

Program

Ordered items
for a battery type.

PGQ19 / v1.0
Example stepItemModel packageModel version
01MR-01Connection Model Av1.0
02MR-02Connection Model Av1.0
03MR-03Connection Model Bv1.0

One item,
one model package.

The model must support all required item criteria.

Reordering items does not, by itself, require a new model.

Three illustrative items explain the relationship. The scope remains 32 CAD inventory entries. Shared models require validation at each point.

How it works / 10 of 12

Inspection Records and Evidence

Each session records battery type, program version, items, timestamps, condition and sequence results, and image evidence. The battery serial number is recorded separately when available.

HISTORY SCREEN ILLUSTRATION / ILLUSTRATIVE DATA
Inspection HistoryIllustrative data
ENGINEERING & QUALITY
SESSION ID

DEMO-SESSION-0002

PGQ19 / program v1.0 / illustrative sequence

NG

Affected item / MR-03

Item conditionSeated and lockedSequence resultMR-03 completed before MR-02

ILLUSTRATIVE EVENT LOG

01MR-01 completed
02MR-03 completed while MR-02 was incomplete
Module-row CAD detail, not an inspection image

CAD illustration; inspection image not yet available.

Linked reinspection

Linked to the original session. Rechecking the final condition does not clear the original sequence NG.

Illustrated record relationship; no completed rework result is claimed.

Enlarge screen illustration

Final condition
A final image supports the connection condition assessment.

Assembly sequence
Timestamped events and related images or video clips.

Results and evidence are stored before outputs are sent. Authorized manual release is recorded separately, with the reason and responsible person.

Delivery / 11 of 12

Implementation and Acceptance Testing

INSPECTION SYSTEM IMPLEMENTATION
01

Point mapping and SOP review

Inspection matrix and final-condition criteria.

02

Module-row development

Test eight connectors and the application workflow.

03

Extension to other zones

Test BMS, HVIL and busbar inspection.

04

Integration and acceptance

Station outputs, records and operating instructions.

TEST TARGETS / ORIGINAL PROPOSAL
MeasureTarget
Precision and recall for locked/unlocked classificationEach ≥98%
Detection of deliberately introduced faults≥95%
False rejection of conforming units≤2%
Response after the hand leaves the zone≤1 second

Proposed targets, not project test results. Test methods, sample sizes and acceptance criteria will be agreed before testing.

Development starts with the module-row.

The production sequence across zones follows the customer SOP. Test results will be reported by zone and fault type.

Delivery / 12 of 12

Items for Agreement

Assembly sequence and condition inspection,
with operator guidance and traceable evidence.

TopicAgreement required
Inventory and drawingsMapping of the 32 entries to inspection points.
SOP and final conditionMandatory sequence and completion criteria for each item.
Identification and programsBarcode format, battery type and serial number where available.
Station integrationResult interface and evidence storage requirements.
NG handlingAuthorized roles, unit disposition and reinspection procedure.

These agreements define the system configuration and test plan.